Dual Point
Underground Storage Tank Equipment
Narrow Your Results
Mfr / Trade Name
Category - Main
Manholes & Spill Containers
Containment Sumps, Monitoring Wells & Flex Connectors
Submersible Pumps, Motors & Leak Detectors
Valves, Drop Tubes & Vents
Accessory
Type
Size
Tank Diameter
Bury Depth
Length
- List View
- Gallery View
Page of 2 |
R/J Standard Pump Repair Kit
Item No. 344-002-5
Includes 323-001-5 Non-AG Functional Element and O-Rings, 144-193-1 Packer Discharge Seal, and 144-183-5 Red Check Valve with spring.
4 Inch Dual Point Carb Approved Overfill Prevention Valve (E85 M85) (Does Not Include Lower Drop Tube)
Item No. 61SOM-412C-EVR
For tanks up to 10 Foot
Defender Series 11 Foot Long Sectional/Collapsible Remote Testing Tool
Item No. 708534901
Remote Testing Tool allows for primary functionality testing of the magnetically-coupled actuator system without having to remove the entire OPV assembly from the riser.
4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial
Item No. 71SO-4000
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial
Item No. 71SO-400C
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
4 inch 71SO Series CARB EVR Certified Vaportight Testable OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial
Item No. 71SO-400CT
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial
Item No. 71SO-4010
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 12 Foot Diameter Tank With 10 Foot Burial
Item No. 71SO-420C
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
4 inch 71SO Series CARB EVR Certified Vaportight E85-Compatible OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial
Item No. 71SOM-412C
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
2 Inch NPT Thread-On Aluminum Pressure Vacuum Vent 2-1/2 - 6 Inch Range Water Column Pressure 6 - 10 Inch Range Vacuum
Item No. A0084-038
Is an internal pressure vacuum valve that restricts vaopr escape during product drops.
Overfill Prevention Valve Dual Point Vapor-Tight 4 Inch X 13 Foot [Evr]
Item No. A1100EVR-055
Screw together style
Overfill Prevention Valve Dual Point Vapor-Tight 4 Inch X 15 Foot [Evr]
Item No. A1100EVR-056
Screw together style
2 Inch O-Ring Seal Pressure Vacuum Vent
Item No. 80230302
Vent rates of 8000 cubic feet per hour and vent at 13.8 in WC of pressure and 0.8 in WC of vacuum.
3 Inch Thread-On 2-1/2 Inch To 6 Inch Water Column Pressure Vacuum Vent
Item No. 623V-3203
Pressure Vacuum Vents are installed on the top of vent pipes from underground or above ground fuel storage tanks
2 Inch Pressure Vacuum Vent Thread On 8 Ounce Pressure 1/2 Ounce Vacuum
Item No. 523V-1100
Factory preset and tested settings
Dual Point Autolimiter II Overfill Prevention Valve 5 Foot Upper Tube / 8 Foot Lower Tube
Item No. 70849101
Up to 10 foot diameter tank
2 Inch Thread-On Pressure/Vacuum Vent 3 Inch Wcp-8 Inch Wcv
Item No. 4885
Incorporates 3 separate valves to control over-pressure and vacuum conditions that arise in storage tanks.
2 Inch Thread-On 2-1/2 Inch To 6 Inch Water Column Pressure Vacuum Vent
Item No. 623V-2203
Pressure Vacuum Vents are installed on the top of vent pipes from underground or above ground fuel storage tanks
2 Inch Pressure Vacuum Vent Thread On 3 Inch Water Column Pressure 8 Inch Water Column Vacuum
Item No. 523V-2203
Factory preset and tested settings