1 Inch X 1-1/2 Inch Vapor Saver Shear Valve With Poppet (Double Poppet ) With Containment Threads

1 Inch X 1-1/2 Inch Vapor Saver Shear Valve With Poppet (Double Poppet ) With Containment Threads

Poppeted models afford additional protection by preventing the release of vapors from the dispenser internal piping

Quick Info
4 inch 61SOC Series Single-Point Coaxial Non-Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

4 inch 61SOC Series Single-Point Coaxial Non-Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

Quick Info
4 inch 61SOC Series Single-Point Coaxial Non-Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

4 inch 61SOC Series Single-Point Coaxial Non-Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

Quick Info
4 inch 61SOP Series Single-Point Poppeted Coaxial CARB-Approved OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

4 inch 61SOP Series Single-Point Poppeted Coaxial CARB-Approved OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

Quick Info
4 inch 61SOP Series Single-Point Poppeted Coaxial CARB-Approved OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

4 inch 61SOP Series Single-Point Poppeted Coaxial CARB-Approved OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

Quick Info
4 inch 61SOR Series Dual-Point Non-Vaportight Remote Fill OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank

4 inch 61SOR Series Dual-Point Non-Vaportight Remote Fill OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank

The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

Quick Info
4 inch 61SOR Series Dual-Point Remote Fill OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank

4 inch 61SOR Series Dual-Point Remote Fill OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank

The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

Quick Info
Defender Series CARB Approved Overfill Prevention Valve With 5 Foot Top Drop Tube And 10 Foot Bottom Drop Tube

Defender Series CARB Approved Overfill Prevention Valve With 5 Foot Top Drop Tube And 10 Foot Bottom Drop Tube

Magnetically-coupled actuator system provides positive shutoff at a broad range of flow rates and eliminates any pentetrations in the valve making it both vapor and leak tight.

Quick Info
4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

The OPW 71SO Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

Quick Info
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

The OPW 71SO Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

Quick Info
4 inch 71SO Series CARB EVR Certified Vaportight Testable OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

4 inch 71SO Series CARB EVR Certified Vaportight Testable OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

The OPW 71SO Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

Quick Info
4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

The OPW 71SO Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

Quick Info
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 12 Foot Diameter Tank With 10 Foot Burial

4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 12 Foot Diameter Tank With 10 Foot Burial

The OPW 71SO Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

Quick Info
4 inch 71SO Series CARB EVR Certified Vaportight E85-Compatible OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

4 inch 71SO Series CARB EVR Certified Vaportight E85-Compatible OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

The OPW 71SO Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

Quick Info
2 Inch Ast Overfill Prevention Valve With Part F Adapter 2 Inch Shut-Off Height

2 Inch Ast Overfill Prevention Valve With Part F Adapter 2 Inch Shut-Off Height

Prevents overfilling storage tanks by providing a positive shut-off during a pressurized fill. installs in a 2 inch Female threaded opening at the fill port of a storage tank

Quick Info
Overfill Prevention Valve Coaxial Vapor-Tight Self-Sealing 4 Inch X 13 Foot With Cap And A0089 Adapter

Overfill Prevention Valve Coaxial Vapor-Tight Self-Sealing 4 Inch X 13 Foot With Cap And A0089 Adapter

Includes A0097-005 Tight Fill Cap And An A0089-001 Tight Fill Adapter

Quick Info
Overfill Prevention Valve Coaxial Vapor-Tight Self-Sealing 4 Inch X 15 Foot With Cap & A0089 Adapter

Overfill Prevention Valve Coaxial Vapor-Tight Self-Sealing 4 Inch X 15 Foot With Cap & A0089 Adapter

Includes A0097-005 Tight Fill Cap And An A0089-001 Tight Fill Adapter

Quick Info
Quick Info
Quick Info
Quick Info
Quick Info
2 Inch Overfill Prevention Valve With Part F Male Threaded Aluminum

2 Inch Overfill Prevention Valve With Part F Male Threaded Aluminum

9095SA series overfill prevention valve is designed to prevent the overfilling of liquid storage tanks by providing a positive shut-off during a pressurized fill. Direct Fill Installations Installs on tank top by threading onto a 2 Inch Male NPT riser Installs inside 2 inc Morrison model 516 or 518 tank top spill container Remote Fill Installations Valve has 2 inch female NPT inlet threads for installation piping to remote fill point