Morrison Brothers
OPW Fueling Components
Narrow Your Results
Mfr / Trade Name
Category - Main
Caps & Adapters
Containment Sumps, Monitoring Wells & Flex Connectors
Valves, Drop Tubes & Vents
Mechanical Tank Gauges
Flexible Piping
Accessory
Type
Composition
Size
Tank Diameter
Tank Opening
Length
Inlet
Application
Pressure Differential
Voltage
- List View
- Gallery View
Page of 3 |
2 Inch Female NPT Replacement Shear Top For Single-Poppet 10RF-2001 Valve
Item No. 10RFT-5742
2 Inch Male NPT 10 Series Double-Poppet Emergency Shut-Off Shear Valve
Item No. 10RMP-2004
2 Inch Angle Check Valve - Single Poppet Spring Loaded
Item No. 137-0300AV
Fitted with a light spring & soft seat made for standard check valve applications
2 Inch Tee Double Outlet Vent Threaded Female NPT
Item No. 155-0500AV
Aluminum t-style vent used primarily on small fuel oil storage tanks
2 Inch Anti-Syphon Valve 5 To 10 Foot Head Pressure
Item No. 199ASV-2200
Factory-adjusted hydrostatic head pressure settings
2 Inch Anti-Syphon Valve 10 To 15 Foot Head Pressure
Item No. 199ASV-3200
Factory-adjusted hydrostatic head pressure settings
2 Inch Full Port 2-Way Brass Ball Valve
Item No. 21BV-0200
Used throughout fueling systems where a shut-off point is desirable to isolate a section of the piping system
2 Inch Swing Check Valve - Threaded Brass
Item No. 246A-0200AV
Designed to prevent backflow in horizontal piping systems. Swing check valve allow liquid to flow in a single direction
2 Inch Swing Check Valve - Threaded Brass With Thermal Expansion Relief At 25 Psi
Item No. 246A-0600AV
Designed to prevent backflow in horizontal piping systems. Swing check valve allow liquid to flow in a single direction
2 Inch Threaded Ductile Iron Swing Check Valve
Item No. 246ADI-0500AV
Designed to prevent backflow in horizontal piping systems. Swing check valve allow liquid to flow in a single direction
2 Inch Tank Monitor Cap & Adapter With 3/8 Inch Threaded Porthole And Cable Connector
Item No. 305XPA-2200AK
Combination cap and Adapter kit for leak detection systems
2 Inch Tank Monitor Cap & Adapter With 1/2 Inch Port & Cable Connector
Item No. 305XPA-2400AK
Keeps water dirt and debris out of the tank prevents vapors from escaping
2 Inch Single Poppet Foot Valve
Item No. 334-0400AV
Installed at the inlet of a suction line bottom of the storage tank
2 Inch Double Poppet Foot Valve
Item No. 335A-0200AV
Installed at the inlet of a suction line normally at the bottom of the storage tank as a prime holding valve.
2 Inch Updraft Vent
Item No. 354-0200AV
Open vent design used on underground and above ground tanks
2 Inch Slip-On Adapter For Series 523 Vents
Item No. 523SA-1002
Converts a 523V and 623V vent to a 2 inch slip on vent
2 Inch Nipple Check Valve With 25 Psi Expansion Relief
Item No. 530-0100AV
One way check valve used to prevent backflow
2 Inch X 6-1/8 Inch Ball Float Vent Valve
Item No. 53VML-0060
Ball bloat vent valves protrude into underground storage tanks from extractor fittings at the Stage I vapor return riser pipe or tank vent line during a product delivery as the tank level rises a counterweight stainless steel ball seats on the valve body and restricts flow of vapors back to the transport truck
2 Inch X 12 Inch Ball Float Vent Valve
Item No. 53VML-0120
Ball bloat vent valves protrude into underground storage tanks from extractor fittings at the Stage I vapor return riser pipe or tank vent line during a product delivery as the tank level rises a counterweight stainless steel ball seats on the valve body and restricts flow of vapors back to the transport truck
2 Inch X 18 Inch Ball Float Vent Valve
Item No. 53VML-0180
Ball bloat vent valves protrude into underground storage tanks from extractor fittings at the Stage I vapor return riser pipe or tank vent line during a product delivery as the tank level rises a counterweight stainless steel ball seats on the valve body and restricts flow of vapors back to the transport truck
2 Inch Solenoid Valve Viton Seal 120 Volt Explosion Proof
Item No. 710-02001V
Installed on piping leading from an aboveground tank to prevent accidental siphoning
2 Inch Solenoid Valve Stainless Steel Teflon With 120 Volt/60 Hz Ac Coil
Item No. 710SS-22001V
Installed on piping leading from an aboveground tank to prevent accidental siphoning
2 Inch EVR Clock Gauge With Female Threads And Drop Tube Float
Item No. 818F-0400AGEVR
Used to measure liquid levels in aboveground storage tanks.