4 inch 61SOP Series Single-Point Poppeted Coaxial CARB-Approved OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

4 inch 61SOP Series Single-Point Poppeted Coaxial CARB-Approved OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

Quick Info
4 inch 61SOP Series Single-Point Poppeted Coaxial CARB-Approved OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

4 inch 61SOP Series Single-Point Poppeted Coaxial CARB-Approved OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

Quick Info
4 Inch X 13 Foot Poppeted Coaxial Fill Drop Tube

4 Inch X 13 Foot Poppeted Coaxial Fill Drop Tube

Poppeted coaxial fill drop tube is similar to the 61TC but is spring-loaded

Quick Info
Coaxial Reconnectable Breakaway Vapor Valve Carb Evr Certified

Coaxial Reconnectable Breakaway Vapor Valve Carb Evr Certified

California Air Resource Board certified executive order VR-203-N and VR-204-N

Quick Info
3 Inch Thread-On 2-1/2 Inch To 6 Inch Water Column Pressure Vacuum Vent

3 Inch Thread-On 2-1/2 Inch To 6 Inch Water Column Pressure Vacuum Vent

Pressure Vacuum Vents are installed on the top of vent pipes from underground or above ground fuel storage tanks

Quick Info
Quick Info
2 Inch Thread-On 2-1/2 Inch To 6 Inch Water Column Pressure Vacuum Vent

2 Inch Thread-On 2-1/2 Inch To 6 Inch Water Column Pressure Vacuum Vent

Pressure Vacuum Vents are installed on the top of vent pipes from underground or above ground fuel storage tanks

Quick Info
Quick Info
Quick Info