Dispenser Pan Sensor
Monitoring Systems
Narrow Your Results
Mfr / Trade Name
Category - Main
Sensor
Type
Fuel Type
Length
- List View
- Gallery View
| Page of 1 |
Solid-State Discriminating Dispenser Pan Sensor
Item No. 794380-320
Used On TLS-350 and TLS-450
Discriminating Dispenser Sump Brite Sensor
Item No. FMP-DDS
Installs in dispenser pans and containment sumps.
11 Inch Hydrostatic Interstitial Brine Brite Sensor For EVO550 EVO5000 EVO600 And EVO6000 Series
Item No. FMP-HIS
Detects leaks in double wall tanks where the interstitial space is filled with liquid brine solution.
21 Inch Hydrostatic Interstitial Brine Brite Sensor For EVO550 EVO5000 EVO600 And EVO6000 Series
Item No. FMP-HIS-XL
Detects leaks in double wall tanks where the interstitial space is filled with liquid brine solution.
21 Inch Hydrostatic Interstitial Brine Brite Sensor For EVO200 EVO400 EVO600 And EVO6000 Series
Item No. FMP-HIS-XL-U
Detects leaks in double wall tanks where the interstitial space is filled with liquid brine solution.
Dual-Point Single-Float Hydrostatic Interstitial Reservoir Sensor With 12 Foot Cable And Vented Riser Cap Assembly For Brine-Filled Doublewall Tanks
Item No. 794380-303
The Dual-Point Hydrostatic Reservoir Sensor accurately detects fluid level change in the reservoir and interstice of a double wall storage tank. The Dual-Point Hydrostatic Reservoir Sensor is ideal for high groundwater areas, and can differentiate between a high level alarm condition and a low level alarm condition. If an inner-wall leak occurs, the brine seeps into the tank triggering a low-level alarm, if an outer wall leak occurs, fluid seeps into the interstice triggering a high-level alarm. Key Features Withstands removal from reservoir several times a year without sensor damage Clear plastic housing for visual inspection or float operations Rests in salt brine solution of up to 30% calcium chloride Meets California&rsquos requirement for secondary space monitoring for tanks as required by AB 2481
Single-Point Single-Float Hydrostatic Interstitial Reservoir Sensor With 12 Foot Cable And Vented Riser Cap Assembly For Brine-Filled Doublewall Tanks
Item No. 794380-301
The Single-Point Hydrostatic Reservoir Sensor accurately detects fluid level change in the reservoir and interstice of a double wall storage tank. The Single-Point has one float and can be used in low groundwater locations. With the Single-Point Hydrostatic Sensor if either an inner or outer leak occurs the brine level decreases and a low-level alarm is triggered. If an inner-wall leak occurs, the brine seeps into the tank triggering a fuel alarm, or if the outer wall leaks, the brine seeps out of the tank interstice triggering a fuel alarm. Key Features Clear plastic housing for visual inspection or float operations Leak in inner or outer wall triggers a low level alarm in low groundwater areas Meets California&rsquos requirement for secondary space monitoring for tanks as required by AB 2481
Solid State Dispenser Pan Sensor Non-Discriminating
Item No. 794380-321
Used On TLS-350 and TLS-450
Position Sensitive Pan / Sump Sensor 12 Foot Cable E85 Approved
Item No. 794380-323
Used On TLS-350 and TLS-450
Single Float Non-Discriminating Stand Alone Sensor With Dispenser Control Interface
Item No. 847970-001
Connects directly to the dispenser wiring, no console required. Mounting brackets are required 330020-012. CUL Listed.
Single Float Non-Discriminating Stand Alone Sensor With Dispenser Control Interface
Item No. 847990-001
Connects directly to the dispenser wiring, no console required. Mounting brackets are required 330020-012. UL Listed.
