Solid-State Discriminating Containment Sump Sensor
Item No. 794380-350
Used On TLS-350 and TLS-450
Product Distinguishing Sensor For Monitoring Containment Sumps Dispenser Pans Interstice Of Steel Tanks & Other Containment Areas (Comes With 12 Of Cable)
Item No. BX-PDS
Bright Eye (BX) sensor for sumps dispenser pans and containment areas
11 Inch Hydrostatic Interstitial Brine Brite Sensor For EVO550 EVO5000 EVO600 And EVO6000 Series
Item No. FMP-HIS
Detects leaks in double wall tanks where the interstitial space is filled with liquid brine solution.
21 Inch Hydrostatic Interstitial Brine Brite Sensor For EVO550 EVO5000 EVO600 And EVO6000 Series
Item No. FMP-HIS-XL
Detects leaks in double wall tanks where the interstitial space is filled with liquid brine solution.
21 Inch Hydrostatic Interstitial Brine Brite Sensor For EVO200 EVO400 EVO600 And EVO6000 Series
Item No. FMP-HIS-XL-U
Detects leaks in double wall tanks where the interstitial space is filled with liquid brine solution.
Dual-Point Single-Float Hydrostatic Interstitial Reservoir Sensor With 12 Foot Cable And Vented Riser Cap Assembly For Brine-Filled Doublewall Tanks
Item No. 794380-303
The Dual-Point Hydrostatic Reservoir Sensor accurately detects fluid level change in the reservoir and interstice of a double wall storage tank. The Dual-Point Hydrostatic Reservoir Sensor is ideal for high groundwater areas, and can differentiate between a high level alarm condition and a low level alarm condition. If an inner-wall leak occurs, the brine seeps into the tank triggering a low-level alarm, if an outer wall leak occurs, fluid seeps into the interstice triggering a high-level alarm. Key Features Withstands removal from reservoir several times a year without sensor damage Clear plastic housing for visual inspection or float operations Rests in salt brine solution of up to 30% calcium chloride Meets California&rsquos requirement for secondary space monitoring for tanks as required by AB 2481
Single-Point Single-Float Hydrostatic Interstitial Reservoir Sensor With 12 Foot Cable And Vented Riser Cap Assembly For Brine-Filled Doublewall Tanks
Item No. 794380-301
The Single-Point Hydrostatic Reservoir Sensor accurately detects fluid level change in the reservoir and interstice of a double wall storage tank. The Single-Point has one float and can be used in low groundwater locations. With the Single-Point Hydrostatic Sensor if either an inner or outer leak occurs the brine level decreases and a low-level alarm is triggered. If an inner-wall leak occurs, the brine seeps into the tank triggering a fuel alarm, or if the outer wall leaks, the brine seeps out of the tank interstice triggering a fuel alarm. Key Features Clear plastic housing for visual inspection or float operations Leak in inner or outer wall triggers a low level alarm in low groundwater areas Meets California&rsquos requirement for secondary space monitoring for tanks as required by AB 2481
Single Point Mini-Hydrostatic Sensor For Brine-Filled Double-Wall Sumps
Item No. 794380-304
Used On TLS-350 and TLS-450
12 Inch Magnetostrictive Dual-Float Discriminating Level Indicating Containment Sump Sensor With 10 Foot Cable
Item No. 857080-111
The Veeder Root Mag Sump Sensor quickly and accurately detects the presence and the amount of water and/or fuel in the containment sump or dispenser pan. Using proven magnetostrictive technology to detect hydrocarbons or water, the Mag Sump Sensor produces fast reaction and recovery times, which eliminates costly and unwarranted service calls and sensor replacements. Features Detect and pinpoint fluid type in containment areas to allow for smart dispatching Increase site uptime in locations where shutdown is not required if only water is detected Single module for two- and three-wire sensors provides flexibility for users to monitor multiple sensor types High-grade polymer housing provides enhanced corrosion resistance and fuel compatibility Robust and rugged screw-in connector allows simplified installation and easy inspection Alarm notification upon presence of liquid in the containment area and/or dispenser pan Alarm conditions indicated by audible alarm with displayed and printed message on the console Record of past alarms available as part of the Alarm History Report with the TLS-450PLUS and TLS4 Series consoles