Foot Valve
Fill Adapter
Narrow Your Results
Mfr / Trade Name
Category - Main
Valves, Drop Tubes & Vents
Accessory
Type
Composition
Size
Tank Diameter
Tank Opening
Bury Depth
Length
Inlet
- List View
- Gallery View
Page of 3 |
3/4 Inch Single Poppet Foot Valve
Item No. 334-0100AV
Installed at the inlet of a suction line bottom of the storage tank
1 Inch Single Poppet Foot Valve
Item No. 334-0200AV
Installed at the inlet of a suction line bottom of the storage tank
1-1/2 Inch Single Poppet Foot Valve
Item No. 334-0300AV
Installed at the inlet of a suction line bottom of the storage tank
2 Inch Single Poppet Foot Valve
Item No. 334-0400AV
Installed at the inlet of a suction line bottom of the storage tank
1-1/2 Inch Double Poppet Foot Valve
Item No. 335A-0100AV
Installed at the inlet of a suction line normally at the bottom of the storage tank as a prime holding valve.
2 Inch Double Poppet Foot Valve
Item No. 335A-0200AV
Installed at the inlet of a suction line normally at the bottom of the storage tank as a prime holding valve.
Tank Bottom Protectors 4 Inch Evr
Item No. 6111-1400
Installed at the bottom of overfill valve or drop tube
Ast Overfill Valve With 2 Inch Flapper Float Arm
Item No. 61FSTOP-2000
The Stopper is designed to prevent overfilling of above ground storage tank (AST) during pressurized-fill (pump on fill)
4 inch 61SOC Series Single-Point Coaxial Non-Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial
Item No. 61SOC-4001
The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.
4 inch 61SOC Series Single-Point Coaxial Non-Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial
Item No. 61SOC-4011
The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.
61SO/71SO Series Overfill Prevention Valve Replacement Float Kit
Item No. 61SOK-0001
Nitrile rubber, closed cell foam construction.
4 inch 61SOP Series Single-Point Poppeted Coaxial CARB-Approved OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial
Item No. 61SOP-4002
The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.
4 inch 61SOP Series Single-Point Poppeted Coaxial CARB-Approved OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial
Item No. 61SOP-4012
The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.
4 inch 61SOR Series Dual-Point Non-Vaportight Remote Fill OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank
Item No. 61SOR-4000
The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.
4 inch 61SOR Series Dual-Point Remote Fill OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank
Item No. 61SOR-400C
The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.
4 Inch Tank Bottom Protector
Item No. 61TP-2398
Installed at the bottom of overfill prevention valves or drop tubes to prevent the tank from damage or leakage at the fill point due to manual tank gauging & erosion from dirt or debris
Defender Series 11 Foot Long Sectional/Collapsible Remote Testing Tool
Item No. 708534901
Remote Testing Tool allows for primary functionality testing of the magnetically-coupled actuator system without having to remove the entire OPV assembly from the riser.
Defender Series CARB Approved Overfill Prevention Valve With 5 Foot Top Drop Tube And 10 Foot Bottom Drop Tube
Item No. 708691902
Magnetically-coupled actuator system provides positive shutoff at a broad range of flow rates and eliminates any pentetrations in the valve making it both vapor and leak tight.
4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial
Item No. 71SO-4000
The OPW 71SO Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial
Item No. 71SO-400C
The OPW 71SO Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.