1-1/2 Inch Female NPT Low Profile Replacement Shear Top For Double-Poppet 10BFP-5726 Valve
Item No. 10FTP-5701
Female National Pipe Thread (NPT) top connection
2 Inch Female NPT Replacement Shear Top For Single-Poppet 10RF-2001 Valve
Item No. 10RFT-5742
1-1/2 Inch Female NPT Replacement Shear Top For Single-Poppet 10BF-5725 Valve
Item No. 10RFT-5750
Replacement top for 10BF-5725
2 Inch Male NPT 10 Series Double-Poppet Emergency Shut-Off Shear Valve
Item No. 10RMP-2004
1-1/2 Inch Male NPT Replacement Shear Top For Single-Poppet 10BM-5825 Valve
Item No. 10RMT-5850
1-1/2 Inch Male NPT Replacement Shear Top For Double-Poppet 10RMTP-5851 Valve
Item No. 10RMTP-5851
Replacement top for 10BHMCP-5830
1-1/2 Inch Full Port Two-Way Ball Valve
Item No. 21BV-0150
Used throughout fueling systems where a shut-off point is desirable to isolate a section of the piping system
2 Inch Full Port 2-Way Brass Ball Valve
Item No. 21BV-0200
Used throughout fueling systems where a shut-off point is desirable to isolate a section of the piping system
1-1/2 Inch Open Vent Upward Aluminum
Item No. 23-0044
Installed on the top of vent pipes from underground or aboveground fuel storage tanks always open to the atmosphere to allow any pressure or vacuum in the tank to vent
2 Inch Slip-On Adapter For Series 523 Vents
Item No. 523SA-1002
Converts a 523V and 623V vent to a 2 inch slip on vent
2 Inch X 6-1/8 Inch Ball Float Vent Valve
Item No. 53VML-0060
Ball bloat vent valves protrude into underground storage tanks from extractor fittings at the Stage I vapor return riser pipe or tank vent line during a product delivery as the tank level rises a counterweight stainless steel ball seats on the valve body and restricts flow of vapors back to the transport truck
2 Inch X 12 Inch Ball Float Vent Valve
Item No. 53VML-0120
Ball bloat vent valves protrude into underground storage tanks from extractor fittings at the Stage I vapor return riser pipe or tank vent line during a product delivery as the tank level rises a counterweight stainless steel ball seats on the valve body and restricts flow of vapors back to the transport truck
2 Inch X 18 Inch Ball Float Vent Valve
Item No. 53VML-0180
Ball bloat vent valves protrude into underground storage tanks from extractor fittings at the Stage I vapor return riser pipe or tank vent line during a product delivery as the tank level rises a counterweight stainless steel ball seats on the valve body and restricts flow of vapors back to the transport truck
1-1/2 Inch Vertical Check Valve With Shear Groove (E85)
Item No. 70-0070
OPW Vertical Check Valves are installed the inlet to the pump in the dispenser island to maintain prime
1-1/2 Inch Vertical Check Valve With Test Port And Shear Groove Boss Mount (E85)
Item No. 70S-0075
OPW Vertical Check Valves are installed the inlet to the pump in the dispenser island to maintain prime
2 Inch NPT Thread-On Aluminum Pressure Vacuum Vent 2-1/2 - 6 Inch Range Water Column Pressure 6 - 10 Inch Range Vacuum
Item No. A0084-038
Is an internal pressure vacuum valve that restricts vaopr escape during product drops.
2 Inch X 12 Inch Male X Male Swivel Flex Connector Stainless Steel
Item No. FC20-SWM12
Flexible Connectors can be used as a convenient means of connecting piping to pumps and dispensers and throughout the piping systems where connections and changes of direction are necessary
2 Inch X 24 Inch Male X Male Swivel Flex Connector Stainless Steel
Item No. FC20-SWM24
Flexible Connectors can be used as a convenient means of connecting piping to pumps and dispensers and throughout the piping systems where connections and changes of direction are necessary
2 Inch Open Vent Upward Aluminum
Item No. 23-0033
Installed on the top of vent pipes from underground or aboveground fuel storage tanks always open to the atmosphere to allow any pressure or vacuum in the tank to vent