Underground Storage Tank Equipment
Aboveground Storage Tank Equipment
Narrow Your Results
Valves, Drop Tubes & Vents
Size
Tank Diameter
Length
- List View
- Gallery View
Page of 1 |
4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial
Item No. 71SO-4010
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 12 Foot Diameter Tank With 10 Foot Burial
Item No. 71SO-420C
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
4 inch 71SO Series CARB EVR Certified Vaportight E85-Compatible OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial
Item No. 71SOM-412C
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
Overfill Prevention Valve Coaxial Vapor-Tight Self-Sealing 4 Inch X 15 Foot With Cap & A0089 Adapter
Item No. A1100-086SP
Includes A0097-005 Tight Fill Cap And An A0089-001 Tight Fill Adapter
Defender Series CARB Approved Overfill Prevention Valve With 10 Foot Top Drop Tube And 8 Foot Bottom Drop Tube
Item No. 708692901
Magnetically-coupled actuator system provides positive shutoff at a broad range of flow rates and eliminates any pentetrations in the valve making it both vapor and leak tight.
Defender Series CARB Approved Overfill Prevention Valve With 10 Foot Top Drop Tube And 10 Foot Bottom Drop Tube
Item No. 708692902
Magnetically-coupled actuator system provides positive shutoff at a broad range of flow rates and eliminates any pentetrations in the valve making it both vapor and leak tight.
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial
Item No. 71SO-410C
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
4 inch 71SO Series CARB EVR Certified Vaportight Testable OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial
Item No. 71SO-410CT
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.