7-1/2 Inch X 8 Inch X 1/4 Inch O-Ring
Item No. 072-718-1
Repair part for Red Jacket "Standard" submersible turbines
Functional Element O-Ring Kit
Item No. 172-003-5
Compatible with all standard fuels including gasoline with up to 15% ethanol
2 Inch LCX Containment Termination
Item No. 22469205
Installs in one half the time of conventional fiberglass pipe
8 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244O-0600AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
8 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton B O-Ring EVR Approved UL 2583 And ULC Listed
Item No. 244O-0600AVEVR
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
6 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0050AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
8 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0100AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
10 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0400AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
3 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0050AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
4 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0100AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
6 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0200AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
8 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0600AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
8 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton B O-Ring EVR Approved UL 2583 And ULC Listed
Item No. 244OM-0600AVEVR
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
O-Ring Fluro
Item No. 400333340
Used to seal lowest portion of the discharge manifold assembly
4 Inch LCX Containment Termination
Item No. 44469205
Proven reliable fiberglass pipe system
2 Inch UPP x 1-1/2 Inch Male NPT Termination Fitting UL-971 Listed
Item No. 91-063-1 NPT-U