Assembled Set
8 Ounce Pressure Setting
Narrow Your Results
Mfr / Trade Name
Category - Main
Sensor
Dispenser Maintenance
Submersible Pumps, Motors & Leak Detectors
Valves, Drop Tubes & Vents
Fiberglass
Semi-Rigid
Accessory
Windshield
Type
Composition
Size
Tank Diameter
Bury Depth
Riser Length
Micron Size
Length
Horse Power
Application
- List View
- Gallery View
Page of 3 |

10 Micron Multi-Fuel Ultimate Defense Particulate Removal And Water Or Phase Separation Detection Spin-On Petroleum Dispenser Filter 1 Inch-12 Thread - 3/4 Inch Flow (70122)
Item No. 300MB-10
Removes particulate and detects free water or emulsified water or phase separation in Gasoline and Ethanol blends up to 25%.

10 Micron Multi-Fuel Ultimate Defense Particulate Removal And Water Or Phase Separation Detection Spin-On Petroleum Dispenser Filter 1-1/2 Inch-16 Thread - 1 Inch Flow (70120)
Item No. 400MB-10
Removes particulate and detects free water emulsified water or phase separation in Gasoline and Ethanol blends up to 25%.

30 Micron Multi-Fuel Ultimate Defense Particulate Removal And Water Or Phase Separation Detection Spin-On Petroleum Dispenser Filter 1 Inch-12 Thread - 3/4 Inch Flow (70018)
Item No. 300MB-30
Removes particulate and detects free water emulsified water or phase separation in Gasoline and Ethanol blends up to 25%.

30 Micron Multi-Fuel Ultimate Defense Particulate Removal And Water Or Phase Separation Detection Spin-On Petroleum Dispenser Filter 1-1/2 Inch-16 Thread - 1 Inch Flow (70106)
Item No. 400MB-30
Removes particulate and detects free water emulsified water or phase separation in Gasoline and Ethanol blends up to 25%.

8 Inch Squeegee Head With 15 Inch Black Plastic Handle
Item No. WS1524U
8 inch squeegee head

8 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244O-0600AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

8 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton B O-Ring EVR Approved UL 2583 And ULC Listed
Item No. 244O-0600AVEVR
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

6 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0050AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

8 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0100AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

10 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0400AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

3 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0050AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

4 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0100AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

6 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0200AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

8 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0600AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

8 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton B O-Ring EVR Approved UL 2583 And ULC Listed
Item No. 244OM-0600AVEVR
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

Defender Series 11 Foot Long Sectional/Collapsible Remote Testing Tool
Item No. 708534901
Remote Testing Tool allows for primary functionality testing of the magnetically-coupled actuator system without having to remove the entire OPV assembly from the riser.

4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial
Item No. 71SO-4000
The OPW 71SO Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial
Item No. 71SO-400C
The OPW 71SO Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

4 inch 71SO Series CARB EVR Certified Vaportight Testable OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial
Item No. 71SO-400CT
The OPW 71SO Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.

4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial
Item No. 71SO-4010
The OPW 71SO Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.