Veeder Root
Franklin Electric
Narrow Your Results
Mfr / Trade Name
Category - Main
TLS Consoles & Installed Modules
Pressurized Line Leak Detection
Replacement Parts & Spare Modules
Sensor
Submersible Pumps, Motors & Leak Detectors
Type
Size
Riser Length
Length
Horse Power
Application
- List View
- Gallery View
| Page of 2 |
20 Foot Plug And Lead Harness
Item No. 144-091-5
Isolates and protects individual dispensers from wiring shorts or phasing issues
20 Foot Plug And Lead Harness Standard And Quantum AG
Item No. 144-162-5
Isolates and protects individual dispensers from wiring shorts or phasing issues
TLS-450 Continuous Statistical Leak Detection - Installed
Item No. 332972-006
CSLD tank testing software enhancement for TLS-450 console
Isotrol Control Box With Relay
Item No. 880-047-1
Isolates and protects individual dispensers from wiring shorts or phasing issues
120 VOlt IQ Control Box
Item No. 880-051-1
Easy to use and easy to install control for manifold pumps
3/4 HP Fixed-Speed 102 Inch To 162 Inch Quick-Set Adjustable-Length Submersible Turbine Pump With PLLD-Ready Check Valve Without Riser (P75U1 RJ2)
Item No. 410140-002-LESSRISER
The Red Jacket Submersible Turbine Pump (TRJ STP) is designed to optimize fuel flow and dispensing from the storage tank, through the piping, and into the vehicle. The advanced packer manifold is designed for ease of installation and service.
1-1/2 HP Fixed-Speed 104-1/2 Inch To 165 Inch Quick-Set Adjustable-Length Submersible Turbine Pump With PLLD-Ready Check Valve Without Riser (P150U1 RJ2)
Item No. 410141-002-LESSRISER
The Red Jacket Submersible Turbine Pump (TRJ STP) is designed to optimize fuel flow and dispensing from the storage tank, through the piping, and into the vehicle. The advanced packer manifold is designed for ease of installation and service.
2 HP Fixed-Speed 108-1/2 Inch To 168-1/2 Inch Quick-Set Adjustable-Length Submersible Turbine Pump With PLLD-Ready Check Valve Without Riser (P200U1-3 RJ2)
Item No. 410142-002-LESSRISER
The Red Jacket Submersible Turbine Pump (TRJ STP) is designed to optimize fuel flow and dispensing from the storage tank, through the piping, and into the vehicle. The advanced packer manifold is designed for ease of installation and service.
Single-Point Single-Float Hydrostatic Interstitial Reservoir Sensor With 12 Foot Cable And Vented Riser Cap Assembly For Brine-Filled Doublewall Tanks
Item No. 794380-301
The Single-Point Hydrostatic Reservoir Sensor accurately detects fluid level change in the reservoir and interstice of a double wall storage tank. The Single-Point has one float and can be used in low groundwater locations. With the Single-Point Hydrostatic Sensor if either an inner or outer leak occurs the brine level decreases and a low-level alarm is triggered. If an inner-wall leak occurs, the brine seeps into the tank triggering a fuel alarm, or if the outer wall leaks, the brine seeps out of the tank interstice triggering a fuel alarm. Key Features Clear plastic housing for visual inspection or float operations Leak in inner or outer wall triggers a low level alarm in low groundwater areas Meets California&rsquos requirement for secondary space monitoring for tanks as required by AB 2481
Pressurized Line Leak Detector With Swift Check Valve
Item No. 848480-003
Pressurized Line Leak Detection (PLLD) provides automatic 3.0 GPH hourly line testing
2 HP Fixed-Speed 168-1/2 Inch To 228-1/2 Inch Quick-Set Adjustable-Length Submersible Turbine Pump With PLLD-Ready Check Valve Without Riser (P200U1-3 RJ3)
Item No. 410142-003-LESSRISER
The Red Jacket Submersible Turbine Pump (TRJ STP) is designed to optimize fuel flow and dispensing from the storage tank, through the piping, and into the vehicle. The advanced packer manifold is designed for ease of installation and service.
3/4 hp Fixed Speed 57 Inch to 86 Inch Variable Length Submersible Turbine Pump Without Riser (STP75-VL1-00)
Item No. 402006901
Variable length model (VL1) extends from 55 inches to 83 inches and includes a standard model check valve (40 psi relief / 35 psi reset) for MLD and TS-LS300)
3/4 hp Fixed Speed 88 Inch to 149 Inch Variable Length Submersible Turbine Pump Without Riser (STP75-VL2-00)
Item No. 402009901
Variable length model (VL2) extends from 88 inches to 149 inches and includes a standard model check valve (40 psi relief / 35 psi reset)
1-1/2 HP Fixed Speed 91 Inch-152 Inch Variable Length Submersible Turbine Pump Without Riser (402010901)
Item No. STP150-VL2
Variable length model (VL2) extends from 91 inches up to 152 inches fitting 94% of all known installations includes standard model check valve (40 psi pressure relief and 35 psi reset)
1-1/2 HP Variable Length 91 Inch-152 Inch Variable Length Submersible Pump With 19 Inch Riser (STP150-VL2-19)
Item No. 402010919
Variable length model (VL2) extends from 91 inches up to 152 inches fitting 94% of all known installations includes standard model check valve (40 psi pressure relief and 35 psi reset)
3/4 hp Fixed Speed 88 Inch-149 Inch Variable Length Submersible Turbine Pump With Model R Check Valve Without Riser (STPR75-VL2-00)
Item No. 402066901
Factory installed model R check valve (24 psi relief / 22 psi reset) for Veeder Root pressurized line leak detection variable length pump extends from 88 inches up to 149 inches