Piping
Petroleum Containment
Narrow Your Results
Mfr / Trade Name
Category - Main
Fiberglass
- List View
- Gallery View
| Page of 1 |
FRP Series Full Ring Pass-Thru FRP Entry Fitting For 2 Inch LCX Pipe On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-FRP-1F-L2
The Full Ring Pass-Thru FRP New Construction Entry Fitting has a small profile and occupies little space in a crowded sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Small profile saves space in sump. Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
FRP Series Full Ring Pass-Thru FRP Entry Fitting For 2 Inch RTII Pipe On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-FRP-1F-R2
The Full Ring Pass-Thru FRP New Construction Entry Fitting has a small profile and occupies little space in a crowded sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Small profile saves space in sump. Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
SRB Series Split Repair FRP Entry Fitting With Stainless Band Clamp For 2 Inch LCX Pipe On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-SRB-1F-L2
The Split Repair FRP Entry Fitting With Band Clamp makes repairs straight forward and allows for field modification. Features Stainless Band Clamp holds fitting in place and the Retention Rim prevents the clamp from sliding off the fitting while the epoxy cures Can be modified in the field to simplify service work 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
SRB Series Oversize Split Repair FRP Entry Fitting With Stainless Band Clamp For 2 Inch LCX Pipe On Flat Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-SRB-2F-L2
The Oversized Split Repair FRP Entry Fitting With Band Clamp makes repairs straight forward and allows for field modification. Oversized model eliminates need to pair the SRB with a BSO fitting. Features Stainless Band Clamp holds fitting in place and the Retention Rim prevents the clamp from sliding off the fitting while the epoxy cures Can be modified in the field to simplify service work 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
TPP Series Testable Pass-Thru FRP Entry Fitting For 2 Inch LCX Or 3 Inch x 2 Inch RTIIA Pipe On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-TPP-2F-U2
The Testable Pass-Thru New Construction Fitting brings both convenience and innovation for a simple and permanent installation. Dual integrated test ports eliminates the need for a separate test boot to save time, money and space in an already crowded containment sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Universal Fitting is designed to accommodate RTIIA and LCX pipe Allows all Primary and Secondary connections to be inside the sump, eliminating the need for any external pipe joints Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Dual Integrated Test Ports eliminates the need for a separate test boot Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
TPT Series Testable Primary Terminating FRP Entry Fitting For 2 Inch LCX Pipe On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-TPT-2F-L2
The Testable Primary Termination New Construction Fitting brings both convenience and innovation for a simple and permanent installation. An integrated test port eliminates the need for a separate test boot to save time, money and space in an already crowded containment sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Integrated Test Port eliminates the need for a separate test boot Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings