Open
8 Ounce Pressure Setting
Narrow Your Results
Mfr / Trade Name
Submersible Pumps, Motors & Leak Detectors
Valves, Drop Tubes & Vents
Type
Composition
Size
- List View
- Gallery View
| Page of 1 |
1-1/2 Inch Open Vent Upward Aluminum
Item No. 23-0044
Installed on the top of vent pipes from underground or aboveground fuel storage tanks always open to the atmosphere to allow any pressure or vacuum in the tank to vent
8 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244O-0600AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
8 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton B O-Ring EVR Approved UL 2583 And ULC Listed
Item No. 244O-0600AVEVR
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
6 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0050AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
8 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0100AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
10 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0400AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
3 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0050AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
4 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0100AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
6 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0200AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
8 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0600AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
8 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton B O-Ring EVR Approved UL 2583 And ULC Listed
Item No. 244OM-0600AVEVR
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
2 Inch Updraft Vent
Item No. 354-0200AV
Open vent design used on underground and above ground tanks
4 Inch Updraft Vent
Item No. 354-0400AV
Open vent design used on under ground and above ground tanks
TPGC-220 Guardian Series 3-Phase Submersible Pump Smart Controller (220 Volt Supply / 110 Volt Hook)
Item No. 5800103220
Features Compatible with most FE PETRO three phase 3 Hp and 5 Hp fixed speed STPs, as well as comparable competitive STPs. 3-1/2 inch digital LCD provides readable running and fault status for quick troubleshooting. Separate Reset and Silence/Calibrate push buttons provide clear interaction with the controller. Automatically logs the last five abnormal conditions seen in the pumping system. This data is retained in non-volatile memory. Service technicians can quickly view a history of abnormal conditions, which is particularly useful when troubleshooting intermittent conditions. Over voltage protection and enhanced underload detection protects pumping system equipment. With a single press of the Calibrate button, the controller will automatically learn the electrical characteristics of the STP for easy setup or retrofit.
2 Inch Upward V Vent Polyethylene
Item No. A4103-002
Slip-on style attaches to 1.5 inch-2.0 inch pipe with 3 set screws
2 Inch Open Vent Upward Aluminum
Item No. 23-0033
Installed on the top of vent pipes from underground or aboveground fuel storage tanks always open to the atmosphere to allow any pressure or vacuum in the tank to vent
3 Inch Open Vent Upward Aluminum
Item No. 23-0055
Installed on the top of vent pipes from underground or aboveground fuel storage tanks always open to the atmosphere to allow any pressure or vacuum in the tank to vent
6 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton B O-Ring EVR Approved UL 2583 And ULC Listed
Item No. 244O-0200AVEVR
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
4 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244O-0100AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
6 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244O-0200AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
3 Inch Updraft Vent Cap
Item No. 354-0300AV
Open vent design used on under ground and above ground tanks