Dual Point
OPW Fueling Components
Narrow Your Results
Mfr / Trade Name
Category - Main
Manholes & Spill Containers
Valves, Drop Tubes & Vents
Type
Size
Tank Diameter
Bury Depth
- List View
- Gallery View
Page of 1 |
4 Inch Dual Point Carb Approved Overfill Prevention Valve (E85 M85) (Does Not Include Lower Drop Tube)
Item No. 61SOM-412C-EVR
For tanks up to 10 Foot
4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial
Item No. 71SO-4000
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial
Item No. 71SO-400C
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
4 inch 71SO Series CARB EVR Certified Vaportight Testable OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial
Item No. 71SO-400CT
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial
Item No. 71SO-4010
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 12 Foot Diameter Tank With 10 Foot Burial
Item No. 71SO-420C
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
4 inch 71SO Series CARB EVR Certified Vaportight E85-Compatible OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial
Item No. 71SOM-412C
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
Bronze Lever Arm For The 1Sc-2100 Series Sealable Cover
Item No. C04101B
Field replaceable
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial
Item No. 71SO-410C
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.
4 inch 71SO Series CARB EVR Certified Vaportight Testable OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial
Item No. 71SO-410CT
The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.