Underground Storage Tank Equipment
Monitoring Systems

Advanced Tank Gauging Systems Designed For Dependability and Remote Monitoring

Source North America Corporation's tank gauging systems provide the accurate, user-friendly inventory and compliance management tools that today's retail and commercial fuel site operators need to remain both compliant and profitable.

With product solutions from some of the most respected petroleum equipment manufacturers in the industry, our tank gauging systems and accessories are designed to streamline wetstock management. Offering monitoring systems, accessories and replacement parts for ethanol and diesel applications, Source delivers the monitoring equipment fuel marketers need to minimize downtime resulting from leaks and other inventory complications. From industry-leading tank-monitoring consoles that can be managed remotely and probe float kits capable of detecting phase separation, our tank gauging equipment will help ensure that your products are secure and that your site is meeting critical environmental compliance regulations in an efficient manner.

  • List View
  • Gallery View
Sort By:
Results/Page:
Page
of 2
     
Quick Info
Quick Info
Quick Info
Quick Info
2 Inch Female NPT 10 Series Double-Poppet Emergency Shut-Off Shear Valve

2 Inch Female NPT 10 Series Double-Poppet Emergency Shut-Off Shear Valve

Female National Pipe Thread (NPT) top connection

Quick Info
1-1/2 Inch Female NPT Replacement Shear Top For Double-Poppet Valve

1-1/2 Inch Female NPT Replacement Shear Top For Double-Poppet Valve

Old style replacement top for 10BFP-5726. This top had a 5/16 Inch higher profile.

Quick Info
Quick Info
Quick Info
Quick Info
Quick Info
1-1/2 Inch Double Poppet Foot Valve

1-1/2 Inch Double Poppet Foot Valve

Installed at the inlet of a suction line normally at the bottom of the storage tank as a prime holding valve.

Quick Info
2 Inch Double Poppet Foot Valve

2 Inch Double Poppet Foot Valve

Installed at the inlet of a suction line normally at the bottom of the storage tank as a prime holding valve.

Quick Info
Quick Info
1-1/2 Inch NPT Emergency Shut-Off Valve Double Poppet Female E-Coat Agb

1-1/2 Inch NPT Emergency Shut-Off Valve Double Poppet Female E-Coat Agb

UL Listed For Use With E-85 (High Ethanol Blends) And Biodiesel Fuel Blends Under The UL842A and UL842B Standards

Quick Info
Defender Series 11 Foot Long Sectional/Collapsible Remote Testing Tool

Defender Series 11 Foot Long Sectional/Collapsible Remote Testing Tool

Remote Testing Tool allows for primary functionality testing of the magnetically-coupled actuator system without having to remove the entire OPV assembly from the riser.

Quick Info
4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.

Quick Info
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.

Quick Info
4 inch 71SO Series CARB EVR Certified Vaportight Testable OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

4 inch 71SO Series CARB EVR Certified Vaportight Testable OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.

Quick Info
4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.

Quick Info
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 12 Foot Diameter Tank With 10 Foot Burial

4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 12 Foot Diameter Tank With 10 Foot Burial

The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.

Quick Info
4 inch 71SO Series CARB EVR Certified Vaportight E85-Compatible OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

4 inch 71SO Series CARB EVR Certified Vaportight E85-Compatible OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.

Quick Info
Quick Info
Emergency Shear Valve 1-1/2 Inch Double Poppet Female Stainless Steel

Emergency Shear Valve 1-1/2 Inch Double Poppet Female Stainless Steel

Stainless Steel body and top for E85/DEF/ Ultra Low Sulfur Diesel

Quick Info
Quick Info
Displaying: 1 - 24 of 32 results
 
 
 
Go Top