Underground Storage Tank Equipment
Dispenser Equipment

Industry-Leading Hanging Hardware, Dispenser Parts and Maintenance Products

Source North America Corporation is proud to be a leading fuel dispenser parts supplier, helping commercial and retail fuel applications meet their ongoing dispenser maintenance requirements.

Our line of hanging hardware features nozzles, breakaways, swivels and hoses from the most trusted petroleum equipment manufacturers in the industry. Our comprehensive selection of dispenser nozzles for gasoline, diesel, E85 and DEF include automatic and manual nozzles for traditional fueling applications, as well as dispenser nozzles for bulk and aircraft fueling. Our collection of hanging hardware includes a selection of products designed for environmental compliance — from vapor assist dispenser nozzles to low-perm and EVR balance recovery. As a comprehensive fuel dispenser parts supplier, we also offer common dispenser replacement parts and dispenser maintenance products such as dispenser filters and accessories.

User-friendly and attractive fuel islands that keep product flowing are the heart of every retail fuel site. Source dispenser parts ship quickly to encourage maximum uptime and to minimize potential revenue losses.

  • List View
  • Gallery View
Sort By:
Results/Page:
Page
of 1
Quick Info
Quick Info
Quick Info
Quick Info
1-1/2 Inch Vertical Check Valve With Shear Groove (E85)

1-1/2 Inch Vertical Check Valve With Shear Groove (E85)

OPW Vertical Check Valves are installed the inlet to the pump in the dispenser island to maintain prime

Quick Info
Defender Series 11 Foot Long Sectional/Collapsible Remote Testing Tool

Defender Series 11 Foot Long Sectional/Collapsible Remote Testing Tool

Remote Testing Tool allows for primary functionality testing of the magnetically-coupled actuator system without having to remove the entire OPV assembly from the riser.

Quick Info
1-1/2 Inch Vertical Check Valve With Test Port And Shear Groove Boss Mount (E85)

1-1/2 Inch Vertical Check Valve With Test Port And Shear Groove Boss Mount (E85)

OPW Vertical Check Valves are installed the inlet to the pump in the dispenser island to maintain prime

Quick Info
4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.

Quick Info
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.

Quick Info
4 inch 71SO Series CARB EVR Certified Vaportight Testable OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

4 inch 71SO Series CARB EVR Certified Vaportight Testable OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial

The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.

Quick Info
4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

4 inch 71SO Series Non-Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.

Quick Info
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 12 Foot Diameter Tank With 10 Foot Burial

4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 12 Foot Diameter Tank With 10 Foot Burial

The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.

Quick Info
4 inch 71SO Series CARB EVR Certified Vaportight E85-Compatible OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

4 inch 71SO Series CARB EVR Certified Vaportight E85-Compatible OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.

Quick Info
Quick Info
Quick Info
Lifting Handle With Foot Pedal For FL Series Watertight Covers

Lifting Handle With Foot Pedal For FL Series Watertight Covers

Raintight or fully watertight options

Quick Info
Lifting Handle For Raised Covers - Fl42/Fl36

Lifting Handle For Raised Covers - Fl42/Fl36

To easily and safely remove and replace raised covers

Quick Info
Quick Info
4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

4 inch 71SO Series CARB EVR Certified Vaportight OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.

Quick Info
4 inch 71SO Series CARB EVR Certified Vaportight Testable OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

4 inch 71SO Series CARB EVR Certified Vaportight Testable OPV Overfill Prevention Valve For Up To 10 Foot Diameter Tank With 10 Foot Burial

The OPW 71SO Series OPV Overfill Prevention Valve is a 2-Point Shut-off Valve designed to prevent the overfill of UST Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve mechanism is released, closing automatically with the flow. This reduces the flow rate to approximately 5 GPM through a bypass valve. The operator may then stop the filling process and disconnect and drain the delivery hose.If the delivery is not stopped and the liquid rises to about 98 Percent of tank capacity, the bypass valve closes completely. No additional liquid can flow into the tank until the level drops below a reset point.

Displaying: 1 - 19 of 19 results
 
 
 
Go Top