Performance Ink
Bravo
Narrow Your Results
Mfr / Trade Name
Category - Main
Dispenser Replacement Parts
Manholes & Spill Containers
Containment Sumps, Monitoring Wells & Flex Connectors
Fiberglass
Accessory
Decals
Type
Composition
Size
Skirt Length
Color
- List View
- Gallery View
| Page of 8 |
42 Inch Diameter x 3 Foot 6 Inch Tall Closed-Bottom Two-Piece Singlewall FRP Height-Adjustable Octagon Tank Sump With 32 Inch Reducer And 32 Inch Snap-Lock Water Tight Lid - (1) EP-S1.0 Kit Required
Item No. B422-42-S-01
- Can be riser Adapter or reverse flange mounted. UL2447 Listed
2 Tank Vent Box
Item No. B500JPF-2SB
Rigid penetration fittings durable under exposed conditions for 2 inch vent riser
48 Inch x 23-3/4 Inch Gilbarco Encore Retail Dispenser Universal Conversion Frame With Field-Adjustable Drainage Tray 1/2 Inch Anchor Bolts And Frame Caps
Item No. CU-380
- Prevents water intrusion and ensures proper containment of hydraulic cabinet.
1 Gallon Epoxy Bonding Kit
Item No. E154CM
Gel Time 10 minutes at 65 Degrees F 10 minutes at 95 Degrees F Cure Time 2 Hours at 65 Degrees F 45 Minutes at 95 Degrees F
FF Series Double-Sided FRP Flange Pass-Through Entry Fitting For 3/4 Inch Galvanized Conduit On Flat-Wall Singlewall FRP Sump - (1) EP100 Required
Item No. F-07-F
- UL2447 listed. 30-year corrosion warranty.
FF Series Double-Sided FRP Flange Pass-Through Entry Fitting For 1 Inch Galvanized Conduit On Flat-Wall Singlewall FRP Sump - (1) EP100 Required
Item No. F-10-F
- UL2447 listed. 30-year corrosion warranty.
Frp Flat Wall Full Body Fitting For 3/4 Inch Pvc Coated Conduit With Filler (7-11 Specific)
Item No. F-17-RR-7-11
For 3/4 inch Robroy PVC conduit
FF Series Double-Sided FRP Flange Pass-Through Entry Fitting For 2 Inch FRP Pipe On Flat-Wall Singlewall FRP Sump - (1) EP100 Required
Item No. F-20-F
- UL2447 listed. 30-year corrosion warranty.
FF Series Double-Sided FRP Flange Pass-Through Entry Fitting For 4 Inch FRP Pipe On Flat-Wall Singlewall FRP Sump - (2) EP100 Required
Item No. F-40-F
- UL2447 listed. 30-year corrosion warranty.
Wayne Helix Diesel 40 Minimum Cetane Rating Actuator Polycarbonate Overlay With Black Text On Yellow Background
Item No. HELIX-CET-40D
2-1/8 Inch Wide x 1-3/4 Inch Tall
FRP Series Full Ring Pass-Thru FRP Entry Fitting For 1 Inch Galvanized Conduit On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-FRP-1F-C1
The Full Ring Pass-Thru FRP New Construction Entry Fitting has a small profile and occupies little space in a crowded sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Small profile saves space in sump. Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
FRP Series Full Ring Pass-Thru FRP Entry Fitting For 3/4 Inch Galvanized Conduit On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-FRP-1F-C8
The Full Ring Pass-Thru FRP New Construction Entry Fitting has a small profile and occupies little space in a crowded sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Small profile saves space in sump. Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
FRP Series Full Ring Pass-Thru FRP Entry Fitting For 1 Inch PVC Coated Conduit On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-FRP-1F-K1
The Full Ring Pass-Thru FRP New Construction Entry Fitting has a small profile and occupies little space in a crowded sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Small profile saves space in sump. Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
FRP Series Full Ring Pass-Thru FRP Entry Fitting For 3/4 Inch PVC Coated Conduit On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-FRP-1F-K8
The Full Ring Pass-Thru FRP New Construction Entry Fitting has a small profile and occupies little space in a crowded sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Small profile saves space in sump. Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
FRP Series Full Ring Pass-Thru FRP Entry Fitting For 2 Inch LCX Pipe On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-FRP-1F-L2
The Full Ring Pass-Thru FRP New Construction Entry Fitting has a small profile and occupies little space in a crowded sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Small profile saves space in sump. Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
FRP Series Full Ring Pass-Thru FRP Entry Fitting For 3 Inch LCX Pipe On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-FRP-1F-L3
The Full Ring Pass-Thru FRP New Construction Entry Fitting has a small profile and occupies little space in a crowded sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Small profile saves space in sump. Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
FRP Series Full Ring Pass-Thru FRP Entry Fitting For 4 Inch LCX Pipe On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-FRP-1F-L4
The Full Ring Pass-Thru FRP New Construction Entry Fitting has a small profile and occupies little space in a crowded sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Small profile saves space in sump. Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
FRP Series Full Ring Pass-Thru FRP Entry Fitting For 2 Inch RTII Pipe On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-FRP-1F-R2
The Full Ring Pass-Thru FRP New Construction Entry Fitting has a small profile and occupies little space in a crowded sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Small profile saves space in sump. Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
FRP Series Full Ring Pass-Thru FRP Entry Fitting For 3 Inch RTII Pipe On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-FRP-1F-R3
The Full Ring Pass-Thru FRP New Construction Entry Fitting has a small profile and occupies little space in a crowded sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Small profile saves space in sump. Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
SRB Series Split Repair FRP Entry Fitting With Stainless Band Clamp For 1 Inch Galvanized Conduit On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-SRB-1F-C1
The Split Repair FRP Entry Fitting With Band Clamp makes repairs straight forward and allows for field modification. Features Stainless Band Clamp holds fitting in place and the Retention Rim prevents the clamp from sliding off the fitting while the epoxy cures Can be modified in the field to simplify service work 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
SRB Series Split Repair FRP Entry Fitting With Stainless Band Clamp For 3/4 Inch Galvanized Conduit On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-SRB-1F-C8
The Split Repair FRP Entry Fitting With Band Clamp makes repairs straight forward and allows for field modification. Features Stainless Band Clamp holds fitting in place and the Retention Rim prevents the clamp from sliding off the fitting while the epoxy cures Can be modified in the field to simplify service work 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings