Aboveground Storage Tank Equipment
Underground Storage Tank Equipment
Narrow Your Results
Mfr / Trade Name
Valves, Drop Tubes & Vents
Accessory
Type
Composition
Size
Tank Diameter
Tank Opening
Bury Depth
Length
Inlet
Application
- List View
- Gallery View
Page of 4 |
2 Inch Angle Check Valve - Single Poppet Spring Loaded
Item No. 137-0300AV
Fitted with a light spring & soft seat made for standard check valve applications
1-1/2 Inch Anti-Syphon Valve 5 To 10 Foot Head Pressure
Item No. 199ASV-2150
Factory-adjusted hydrostatic head pressure settings
2 Inch Anti-Syphon Valve 5 To 10 Foot Head Pressure
Item No. 199ASV-2200
Factory-adjusted hydrostatic head pressure settings
2 Inch Anti-Syphon Valve 10 To 15 Foot Head Pressure
Item No. 199ASV-3200
Factory-adjusted hydrostatic head pressure settings
1 1/2 Inch Buna Union Check Valve With Screen
Item No. 200AS-15
Easily inserted onto existing union fittings in suction systems
2 Inch Pressure Relief Nipple Check Valve Bronze Viton Seats
Item No. 212VPR-20-3650
Mounted in fuel lines at the submersible pump to hold the prime and prevent premature tripping of mechanical leak detectors
1-1/2 Inch Full Port Two-Way Ball Valve
Item No. 21BV-0150
Used throughout fueling systems where a shut-off point is desirable to isolate a section of the piping system
2 Inch Full Port 2-Way Brass Ball Valve
Item No. 21BV-0200
Used throughout fueling systems where a shut-off point is desirable to isolate a section of the piping system
3 Inch Full Port Two-Way Ball Valve
Item No. 21BV-0300
Used throughout fueling systems where a shut-off point is desirable to isolate a section of the piping system
4 Inch X 2 Inch X 4 Inch Extractor Tee No Cage (E85 Approved)
Item No. 233-4420
Threads into 4 inch NPT opening on an underground storage tank
4 Inch X 2 Inch X 2 Inch X 4 Inch Extractor Cross No Cage (E85 Approved)
Item No. 233-4422
Threads into 4 inch NPT opening on an underground storage tank
4 Inch X 3 Inch X 4 Inch Extractor Tee No Cage (E85 Approved)
Item No. 233-4430
Threads into 4 inch NPT opening on an underground storage tank
4 Inch X 3 Inch X 2 Inch X 4 Inch Extractor Cross No Cage (E85 Approved)
Item No. 233-4432
Threads into 4 inch NPT opening on an underground storage tank
4 Inch X 3 Inch X 3 Inch X 4 Inch Extractor Cross No Cage (E85 Approved)
Item No. 233-4433
Threads into 4 inch NPT opening on an underground storage tank
Test Plug For 233 Series Extractors
Item No. 233VP-6046
Incorporates an O-ring above the threads (on the plug) to isolate the tank from the vent piping system during tan test
1-1/2 Inch Swing Check Valve - Threaded Brass
Item No. 246A-0100AV
Designed to prevent backflow in horizontal piping systems. Swing check valve allow liquid to flow in a single direction
2 Inch Swing Check Valve - Threaded Brass
Item No. 246A-0200AV
Designed to prevent backflow in horizontal piping systems. Swing check valve allow liquid to flow in a single direction
2 Inch Swing Check Valve - Threaded Brass With Thermal Expansion Relief At 25 Psi
Item No. 246A-0600AV
Designed to prevent backflow in horizontal piping systems. Swing check valve allow liquid to flow in a single direction
2 Inch Threaded Ductile Iron Swing Check Valve
Item No. 246ADI-0500AV
Designed to prevent backflow in horizontal piping systems. Swing check valve allow liquid to flow in a single direction
2 Inch Nipple Check Valve With 25 Psi Expansion Relief
Item No. 530-0100AV
One way check valve used to prevent backflow
Ast Overfill Valve With 2 Inch Flapper Float Arm
Item No. 61FSTOP-2000
The Stopper is designed to prevent overfilling of above ground storage tank (AST) during pressurized-fill (pump on fill)
4 inch 61SOC Series Single-Point Coaxial Non-Vaportight OPV Overfill Prevention Valve For Up To 8 Foot Diameter Tank With 5 Foot Burial
Item No. 61SOC-4001
The OPW 61SO Overfill Prevention Valve is a 2-Stage Shut-off Valve designed to prevent the overfill of Underground Storage Tanks by providing a positive shut-off of product delivery. When the liquid level rises to about 95 Percent of tank capacity, the valve automatically slows flow. If the delivery is not stopped and liquid rises to about 98 Percent of tank capacity, the valve closes completely and liquid cannot flow.