Overfill Valves
Aboveground Storage Tank Equipment
Narrow Your Results
Valves, Drop Tubes & Vents
Accessory
Composition
Size
Tank Opening
Inlet
Pressure Differential
Voltage
- List View
- Gallery View
Page of 1 |
Ast Overfill Valve With 2 Inch Flapper Float Arm
Item No. 61FSTOP-2000
The Stopper is designed to prevent overfilling of above ground storage tank (AST) during pressurized-fill (pump on fill)
1 Inch Solenoid Valve Viton Seal 120 Volt/60 Hz Ac Coil
Item No. 710-01001V
Installed on piping leading from an aboveground tank to prevent accidental siphoning
1-1/2 Inch Solenoid Valve Viton Seal 120 Volt
Item No. 710-01501V
Installed on piping leading from an aboveground tank to prevent accidental siphoning
2 Inch Solenoid Valve Viton Seal 120 Volt Explosion Proof
Item No. 710-02001V
Installed on piping leading from an aboveground tank to prevent accidental siphoning
3 Inch Solenoid Valve Viton Seal 120 Volt/60 Hz Volt Ac Coil
Item No. 710-03001V
Installed on piping leading from an aboveground tank to prevent accidental siphoning
1-1/2 Inch Solenoid Valve Stainless Steel Teflon With 120 Volt/60 Hz Ac Coil
Item No. 710SS-21501V
Installed on piping leading from an aboveground tank to prevent accidental siphoning
2 Inch Solenoid Valve Stainless Steel Teflon With 120 Volt/60 Hz Ac Coil
Item No. 710SS-22001V
Installed on piping leading from an aboveground tank to prevent accidental siphoning
2 Inch Ast Overfill Prevention Valve With Part F Adapter 2 Inch Shut-Off Height
Item No. 9095DS-0200AV
Prevents overfilling storage tanks by providing a positive shut-off during a pressurized fill. installs in a 2 inch Female threaded opening at the fill port of a storage tank
2 Inch AST Overfill Prevention Valve With Part A Adapter, 2 Inch Shut-Off Height
Item No. 9095DS-2200AV
Prevents overfilling storage tanks by providing a positive shut-off during a pressurized fill. installs in a 2 inch Female threaded opening at the fill port of a storage tank
2 Inch Overfill Prevention Valve With Part A Female Threaded Aluminum
Item No. 9095SA-0500AV
9095SA series overfill prevention valve is designed to prevent the overfilling of liquid storage tanks by providing a positive shut-off during a pressurized fill. Direct Fill Installations Installs on tank top by threading onto a 2 Inch Male NPT riser Installs inside 2 inc Morrison model 516 or 518 tank top spill container Remote Fill Installations Valve has 2 inch female NPT inlet threads for installation piping to remote fill point
Pressure Regulator Valve With Male NPT Shear Section
Item No. 66430201
Body Cast Iron Selas fluorocarbon Filter Stainless Steel Poppet fluorocarbon
Pressure Regulator Valve With Female NPT Shear Section
Item No. 66430203
Body Cast Iron Selas fluorocarbon Filter Stainless Steel Poppet fluorocarbon
3 Inch Overfill Prevention Valve Evr Approved With 3 Inch Female Threaded X 6 Inch Female Threaded Connection
Item No. 9095AA3300AVEVR
Installed at the fill port of an aboveground storage tank
2 Inch Overfill Prevention Valve Aluminum Body With 3 Inch Female Threads X 4 Inch Female Threads EVR Approved
Item No. 9095AA4200AVEVR
Installed at the fill port of an aboveground storage tank
2 Inch Carb EVR Approved AST Overfill Prevention Valve With 2 Inch Dry Disconnect Adapter x 4 Inch Female NPT
Item No. 9095AA5200AVEVR
Installed at the fill port of an aboveground storage tank
2 Inch Overfill Prevention Valve With Part F Male Threaded Aluminum
Item No. 9095SA-0200AV
9095SA series overfill prevention valve is designed to prevent the overfilling of liquid storage tanks by providing a positive shut-off during a pressurized fill. Direct Fill Installations Installs on tank top by threading onto a 2 Inch Male NPT riser Installs inside 2 inc Morrison model 516 or 518 tank top spill container Remote Fill Installations Valve has 2 inch female NPT inlet threads for installation piping to remote fill point
3/4 Inch Solenoid Valve Viton Seal 24 Volt Dc Coil
Item No. 71024D00751V
- Contact sales for valves with any of the following coil options: 12, 24, 120, 208, 240, and 480 volt AC available; 12, 120 volts DC may be available too
1 Inch 24 Volt DC Normally-Closed Solenoid Valve With FKM Seals
Item No. 71024D0100 1V
Installed on piping leading from an aboveground tank to prevent accidental siphoning