4 Inch Probe Cap With 3/8 Inch Grommet
Item No. 116M-0375
Drilled and tapped to accept 3/8 Inch wire grommet to secure an electronic tang gauge probe in a tank riser pipe
1-1/2 Inch Anti-Syphon Valve 5 To 10 Foot Head Pressure
Item No. 199ASV-2150
Factory-adjusted hydrostatic head pressure settings
2 Inch Anti-Syphon Valve 5 To 10 Foot Head Pressure
Item No. 199ASV-2200
Factory-adjusted hydrostatic head pressure settings
2 Inch Anti-Syphon Valve 10 To 15 Foot Head Pressure
Item No. 199ASV-3200
Factory-adjusted hydrostatic head pressure settings
1-1/2 Inch Open Vent Upward Aluminum
Item No. 23-0044
Installed on the top of vent pipes from underground or aboveground fuel storage tanks always open to the atmosphere to allow any pressure or vacuum in the tank to vent
Aluminum 4 Inch Tank Monitor Cap With 3/8 Inch, EVR Approved
Item No. 305XP-0100ACEVR
Aluminum 4 inch threaded port hole 3/8 inch, 2 pound
2 Inch Tank Monitoring Cap With Port Hole & Cable Connector 3/8 Inch
Item No. 305XP-2200AC
2 Inch Updraft Vent
Item No. 354-0200AV
Open vent design used on underground and above ground tanks
4 Inch Updraft Vent
Item No. 354-0400AV
Open vent design used on under ground and above ground tanks
2 Inch 15 Gallon Ast Remote Spill Container - Female Threaded
Item No. 515-0200AC
Purpose of containing fuel spillage during remote tank filling operations
2 Inch 3-1/2 Gallon Ast Spill Container
Item No. 517-0100AC
Designed to contain small spills that occur at the fill point on aboveground storage tanks
2 Inch 3-1/2 Gallon Ast Spill Container Female Threaded Inlet And Outlet
Item No. 517F-0100AC
Designed to contain small spills that occur at the fill point on aboveground storage tanks
4 Inch Aluminum Tank Monitor Cap And Adapter 3/8 Inch Grommet
Item No. 62M-0375
The 62M Monitoring Probe & Adapter Kit includes a 4 inch side-sealing Adapter 4 inch side-sealing cap (tapped) and a 3/8 inch wire grommet to secure the cable from an electronic tank gauge probe in the tank riser pipe
1-1/2 Inch NPT 90 Degree Anti-Siphon Valve With Thermal Expansion Relief 5-10 Foot W.C.
Item No. 910-1100AV
Normally closed valve helps prevent accidental siphoning of product from tank due to downstream leak below liquid level.
2 Inch NPT 90 Degree Anti-Siphon Valve With Thermal Expansion Relief 0-5 Foot W.C.
Item No. 910-2000AV
Normally closed valve helps prevent accidental siphoning of product from tank due to downstream leak below liquid level.
2 Inch NPT 90 Degree Anti-Siphon Valve With Thermal Expansion Relief 5-10 Foot W.C.
Item No. 910-2100AV
Normally closed valve helps prevent accidental siphoning of product from tank due to downstream leak below liquid level.
2 Inch Upward V Vent Polyethylene
Item No. A4103-002
Slip-on style attaches to 1.5 inch-2.0 inch pipe with 3 set screws
16 Inch x 12 Inch Sign White on Red - Warning No Smoking Within 50 Ft. Of Dispenser
Item No. AS-47
Vinyl White characters on red background
2 Inch Open Vent Upward Aluminum
Item No. 23-0033
Installed on the top of vent pipes from underground or aboveground fuel storage tanks always open to the atmosphere to allow any pressure or vacuum in the tank to vent
3 Inch Open Vent Upward Aluminum
Item No. 23-0055
Installed on the top of vent pipes from underground or aboveground fuel storage tanks always open to the atmosphere to allow any pressure or vacuum in the tank to vent
15 Gallon 12 Gauge Steel AST Remote Spill Container With 3 Inch Female NPT Back Port Post Mount
Item No. 515-0300AC
Purpose of containing fuel spillage during remote tank filling operations
3/4 Inch Anti-Syphon Valve 0 To 5 Foot Head Pressure
Item No. 199ASV-1075
Factory-adjusted hydrostatic head pressure settings