2 Inch Angle Check Valve - Single Poppet Spring Loaded
Item No. 137-0300AV
Fitted with a light spring & soft seat made for standard check valve applications
2 Inch Tee Double Outlet Vent Threaded Female NPT
Item No. 155-0500AV
Aluminum t-style vent used primarily on small fuel oil storage tanks
2 Inch Anti-Syphon Valve 5 To 10 Foot Head Pressure
Item No. 199ASV-2200
Factory-adjusted hydrostatic head pressure settings
2 Inch Anti-Syphon Valve 10 To 15 Foot Head Pressure
Item No. 199ASV-3200
Factory-adjusted hydrostatic head pressure settings
2 Inch Full Port 2-Way Brass Ball Valve
Item No. 21BV-0200
Used throughout fueling systems where a shut-off point is desirable to isolate a section of the piping system
8 Inch Flange Gasket
Item No. 244F-01102G
Gasket to be used with the 244a series flanged Adapter
8 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244O-0600AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
8 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton B O-Ring EVR Approved UL 2583 And ULC Listed
Item No. 244O-0600AVEVR
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
2 Inch Swing Check Valve - Threaded Brass
Item No. 246A-0200AV
Designed to prevent backflow in horizontal piping systems. Swing check valve allow liquid to flow in a single direction
2 Inch Swing Check Valve - Threaded Brass With Thermal Expansion Relief At 25 Psi
Item No. 246A-0600AV
Designed to prevent backflow in horizontal piping systems. Swing check valve allow liquid to flow in a single direction
2 Inch Threaded Ductile Iron Swing Check Valve
Item No. 246ADI-0500AV
Designed to prevent backflow in horizontal piping systems. Swing check valve allow liquid to flow in a single direction
2 Inch Tank Monitoring Cap With Port Hole & Cable Connector 3/8 Inch
Item No. 305XP-2200AC
2 Inch Tank Monitoring Cap With Port Hole & Cable Connector 1/2 Inch
Item No. 305XP-2400AC
Used for fill ports and access to leak detection on fuel storage tanks
2 Inch Single Poppet Foot Valve
Item No. 334-0400AV
Installed at the inlet of a suction line bottom of the storage tank
2 Inch Double Poppet Foot Valve
Item No. 335A-0200AV
Installed at the inlet of a suction line normally at the bottom of the storage tank as a prime holding valve.
2 Inch Updraft Vent
Item No. 354-0200AV
Open vent design used on underground and above ground tanks
4 Inch 7-1/2 Gallon Ast Spill Container With Drain
Item No. 518-0100AC
Designed to contain small spills that occur at the fill point on aboveground storage tanks
2 Inch Slip-On Adapter For Series 523 Vents
Item No. 523SA-1002
Converts a 523V and 623V vent to a 2 inch slip on vent
7 Gallon 4 Inch Ast Spill Containment Manhole White
Item No. 6221-ASTW74
Heavyweight welded base design, welded-hinge with lockable lid
2 Inch Solenoid Valve Viton Seal 120 Volt Explosion Proof
Item No. 710-02001V
Installed on piping leading from an aboveground tank to prevent accidental siphoning