Non-Discriminating
8 Ounce Pressure Setting
Narrow Your Results
Mfr / Trade Name
Category - Main
Submersible Pumps, Motors & Leak Detectors
Valves, Drop Tubes & Vents
Type
Composition
Size
- List View
- Gallery View
| Page of 1 |
8 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244O-0600AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
8 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton B O-Ring EVR Approved UL 2583 And ULC Listed
Item No. 244O-0600AVEVR
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
6 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0050AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
8 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0100AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
10 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0400AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
3 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0050AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
4 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0100AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
6 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0200AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
8 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0600AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
8 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton B O-Ring EVR Approved UL 2583 And ULC Listed
Item No. 244OM-0600AVEVR
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
Non-Discriminating Piping Sump Sensor With 12 Foot Cable
Item No. 794380-208
Used On TLS-350 and TLS-450
6 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton B O-Ring EVR Approved UL 2583 And ULC Listed
Item No. 244O-0200AVEVR
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
Single Float Non-Discriminating Stand Alone Sensor With Dispenser Control Interface
Item No. 847970-001
Connects directly to the dispenser wiring, no console required. Mounting brackets are required 330020-012. CUL Listed.
Single Float Non-Discriminating Stand Alone Sensor With Dispenser Control Interface
Item No. 847990-001
Connects directly to the dispenser wiring, no console required. Mounting brackets are required 330020-012. UL Listed.
Electro-Optic Interstitial Sensor
Item No. FMP-EIS
Installs in sumps double wall tanks or other dry locations where the presence of a liquid indicates a leak has occured.
4 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244O-0100AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
6 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244O-0200AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.
Mag Variable Frequency Controller (5874202800)
Item No. MAG-VFC
- 2 year warranty from date code
