4 Inch x 3 Inch
3 Inch x 2 Inch
Narrow Your Results
Mfr / Trade Name
Category - Main
Manholes & Spill Containers
Valves, Drop Tubes & Vents
Fiberglass
Flexible Piping
Semi-Rigid
Test & Temination Reducers
Type
Composition
Size
Gallon Size
Application
- List View
- Gallery View
| Page of 1 |
5 Gallon Product Vapor Spill Container Manhole Slip On With Plug
Item No. 1-2105
Aluminum cover & designed to accommodate the fuels of the future including methanol and ethanol
5 Gallon Vapor/Spill Containment Manhole Duratuff Base With Cast Iron Cover Slip On With Plug
Item No. 1C-2105
Retro-fit 5 gallon spill containment
5 Gallon Slip-On Spill Containment Manhole With Sealable Cast Aluminum Cover
Item No. 1SC-2105
Designed to prevent product from entering the soil near the fill riser or vapor riser connection on underground storage tanks during normal tank filling or in the event of an overfill
STF Series Split Test FRP Entry Fitting For 3 Inch x 2 Inch RTIIA Pipe On Flat Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-STF-1C-32
The Split Test FRP Entry Fitting can be used to test secondary piping in new construction applications and to replace damaged or deteriorated rubber test fittings in repair applications. Permanently installed STF fitting leaves the secondary open, unlike other options which must be removed after testing. Features Versatile installation - STF fittings can be used in new construction and repair applications.100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
TPP Series Testable Pass-Thru FRP Entry Fitting For 2 Inch LCX Or 3 Inch x 2 Inch RTIIA Pipe On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-TPP-2F-U2
The Testable Pass-Thru New Construction Fitting brings both convenience and innovation for a simple and permanent installation. Dual integrated test ports eliminates the need for a separate test boot to save time, money and space in an already crowded containment sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Universal Fitting is designed to accommodate RTIIA and LCX pipe Allows all Primary and Secondary connections to be inside the sump, eliminating the need for any external pipe joints Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Dual Integrated Test Ports eliminates the need for a separate test boot Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
TPT Series Testable Primary Terminating FRP Entry Fitting For 3 Inch x 2 Inch RTIIA Pipe On Flat-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-TPT-2F-32
The Testable Primary Termination New Construction Fitting brings both convenience and innovation for a simple and permanent installation. An integrated test port eliminates the need for a separate test boot to save time, money and space in an already crowded containment sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Integrated Test Port eliminates the need for a separate test boot Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
TPT Series Testable Primary Terminating FRP Entry Fitting For 3 Inch x 2 Inch RTIIA Pipe On Round-Wall Sump *EP2A Or ADH-300G Adhesive Required*
Item No. PF-TPT-2R-32
The Testable Primary Termination New Construction Fitting brings both convenience and innovation for a simple and permanent installation. An integrated test port eliminates the need for a separate test boot to save time, money and space in an already crowded containment sump. Features 100% fiberglass construction provides superior strength and ensures the fitting will withstand long-term exposure to all fuels, including ethanol Works with angled pipe entries up to 10° for job site adaptability allowing room for misalignment Integrated Test Port eliminates the need for a separate test boot Cost-effective affordable fiberglass fitting with a similar cost to rubber or plastic fittings
3 Inch To 2 Inch FRP Rubber Test Boot With Air Stem/Test Port
Item No. TBA-3020
Used to isolate and air test the interstitial space between the primary and secondary pipe
3 Inch x 2 Inch UPP Primary Singlewall Reducer Fitting UL-971 Listed
Item No. 09-090-063EIF-U
4 Inch X 3 Inch Termination Without Tap (2 Piece)
Item No. 012040-235-3
UL971 listed and also available in 4 inch x 6 inch
3 Inch X 2 Inch Primary Reducer Bushing
Item No. 32370504
Proven reliable fiberglass pipe system
3 Inch X 2 Inch Secondary Containment Reducer With 3/4 Inch Test Port (2 Piece)
Item No. 32387604
Proven reliable fiberglass pipe system
3 Inch X 2 Inch Containment Reducer Ring (3 Piece Combo)
Item No. 32469208
Installs in one half the time of conventional fiberglass pipe
3 Inch X 2 Inch Reducer Bushing Scarfed O.D. X Taper I.D.
Item No. 012030-231-7
UL 971 listed
4 Inch X 3 Inch Concentric Reducer (2 Piece)
Item No. 012040-238-3
UL971 listed and also available in 5 inch x 4 inch
3 Inch x 2 Inch Test Reducer With Stainless Steel Air Test Valve
Item No. PF-RA 3.6X2.4 ASS
F Series Full-Body Taper-By-Slip Pass-Through FRP Entry Fitting With Dual Test Ports And Single Injection Port For 3 x 2 Inch FRP Pipe On Flat-Wall Single Or Doublewall Sump - (2) EP100 Required
Item No. F-32S-T-F
Bonded FRP new construction full-body termination entry fitting for singlewall or doublewall sumps.